Click here to make tpub.com your Home Page

Page Title: REMOVING POWER SUPPLY INTERCONNECT CABLE ASSEMBLY
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-7025-217-30
2-64. REMOVING POWER SUPPLY INTERCONNECT CABLE ASSEMBLY
Turn off power before working on equipment. Failure to do
so can cause serious injury to personnel.
1. Set POWER ON/OFF circuit breaker to
OFF.
2. Disconnect printer from power
source.
3. Separate chassis (para 2-30).
4.
Loosen two screws (1), turning each
screw two turns at a time until
connector P7(2) can be removed from
connector J7(3).
Loosen two screws (4), turning each
5.
screw two turns at a time until con-
nector P8(5) can be removed from
connector J8(6).
Remove cable assembly (7) from power
6.
supply.
2-65. INSTALLING POWER SUPPLY INTERCONNECT CABLE ASSEMBLY
1. Aline connector P8(5) with connector J8(6) and tighten two screws (4), two turns at a time until
the connector is tight.
2. Aline connector P7(2) with connector J7(3) and tighten two screws (1), two turns at a time until
the connector is tight.
3. Join chassis (para 2-31).
2-108

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business