REMOVING FAULT INDICATOR
2-40.
Remove control panel (para 2-32).
1.
Remove heat shrinkable tubing (1) from two wires (2) to gain access to soldered connections.
2.
3. Tag, unsolder, and separate
wires (2) from wires (3).
Remove nut (4).
4.
Remove FAULT indicator (5).
5.
INSTALLING FAULT
2-41.
INDICATOR
Put FAULT indicator (5) in
1.
place on control panel (6).
lnstaJl nut (4).
2.
3.
Install heat shrinkable tubing
(1) (item 8, Appx B) over
wires (2). Solder wires (2)
to wires (3) as tagged. Remove
tags. Slide heat shrinkable
tubing over solder joints and
apply heat.
4.
Install control panel (para
2-81