b. Repairing Power Cable Connector.
WASHER
Remove two screws, two
1.
washers, and two retainers
from flange, noting
that screws enter
from opposite sides
of flange.
2. While clamping sleeve,
turn flange in direc-
tion of arrow and
unscrew.
3. Slide flange with its metal collar back on
cable. This exposes cable shield over narrow-
ing end of sleeve.
4. Roll back cable shield
from narrow end of
sleeve and flatten on
cable.
5. Clamp inside of connector and turn sleeve in direction of
arrow to separate it from connector.
6. Slide motel Collar back
OR
on cable. This exposes
wire Iead to connector.
7. Locate socket insert(s) to be replaced.
CABLE CONNECTOR
FRONT VIEW
8. Replace damaged socket insert(s) (para 2-76).