Click here to make tpub.com your Home Page

Page Title: LOSS OF DC LOOP CURRENT REGULATION
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-5805-387-34-2
MALFUNCTION/SYMPTOM
PROBABLE CAUSE
TEST PROCEDURE
INDICATION
YES
NO
(14) LOSS OF DC LOOP CURRENT
Defective: Loop battery module A5.
REGULATION.
1. With TS-799A/UGM-1 and test cable
+8.0 vdc
Go to 2.
Replace
No. 3 connected (para 2-4),
defective
connect ME-26B/U across RECEIVE
module A5
PULSE of loop battery module A5.
2. Connect ME-26B/U across SEND PULSE of
+0.6 vdc
------------
Replace
loop battery module A5.
defective
module A5
(15) ABNORMAL SCOPE PRESENTATION
Defective: Scope module A2. Receiver module
BUT NORMAL DISCRIMINATOR
A4. Resistor R3.
INDICATION ON TEST METER.
1.Connect the TS-799AIUGM-1 with the
Replace
MESSAGE TRANSMIT switch set to ON
defective
(para 2-4). Connect test cable No. 3
module A2
(para 2-4) and set the modem ONE
WAY/DUPLEX switch to DUPLEX. Set the
MODE SELECTOR switch to 850 HZ and
observe the modem CRT.
2. Set the MODE SELECTOR switch to 85 HZ
Replace
and observe the modem CRT.
defective
module A2
2-21