Click here to make tpub.com your Home Page

Page Title: 20-MA LOOP CURRENT, BUT NO 60- MA LOOP CURRENT.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-5805-387-34-2
MALFUNCTION/SYMPTOM
PROBABLE CAUSE
TEST PROCEDURE
INDICATION
YES
NO
(13) 20-MA LOOP CURRENT, BUT NO 60-
Defective: Dc loop no. 1 switch S7. Dc loop no 2
MA LOOP CURRENT.
Switch S8. Loop battery module A5.
Do all continuity and resistance checks with all power removed.
1. Check continuity of DC LOOP NO. 1 switch
Continuity
Go to 2.
Replace
(fig. FO-8).
defective
switch S7
2. Check continuity of DC LOOP NO. 2 switch
Continuity
Go to 3.
Replace
(fig. FO-8).
defective
switch S8
3. With TS-799A/UGM-1 and test cable
+8.0 vdc
Go to 4.
Replace
No. 3 connected (para 2-4),
defective
connect ME-26B/U across RECEIVE
module A5
PULSE of loop battery module A5.
4. Connect ME-26BIU across SEND PULSE of
+0.6 vdc
-----------
Replace
loop battery module A5.
defective
module A5
2-20

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business