TM 11-5805-387-34-2
MALFUNCTION/SYMPTOM
PROBABLE CAUSE
TEST PROCEDURE
INDICATION
YES
NO
5. Connect ME-26B/U between pin F of
Continuity
Go to 6.
Replace
connector J2 and terminal 18 of board A6;
defective
check for continuity.
connector J2
6. Connect ME-26B/U between pin F of
Continuity
Go to 7.
Replace
connector J3 and terminal 26 of board A6;
defective
check for continuity.
connector J3
7. Connect ME-26B/U between pin F of
Continuity
Go to 8.
Replace
connector J4 and terminal 26 of board A6;
defective
check for continuity.
connector J4
8. Connect ME-26B/U between terminals 5
4 ohms 2
Go to 9.
Replace
and 18 on board A6; measure resistance.
defective
board A6
9. Connect ME-26B/U between terminals 10
4 ohms 2
------------
Replace
and 26 on board A6; measure resistance.
defective
board A6