TM 11-5805-387-34-2
MALFUNCTION/SYMPTOM
PROBABLE CAUSE
TEST PROCEDURE
INDICATION
YES
NO
(3) NO + 20 VOLTS DC METER INDICATION
Defective: METER M1. Circuit board A7. Meter function
switch S3.
1. Drop front panel down (para 2-9);
+20 vdc
Replace
Go to 2.
connect ME-26B/U between meter M1
defective
posts.
meter (para 3-8).
2. Set METER FUNCTION switch to RCV
+20 vdc
Go to 3.
Replace
LEVEL. Remove cover of circuit board A7
defective
by removing three screws and three washers.
board A7
Connect ME-26B/U between terminal 3 and
terminal 7 of board A7.
Do all continuity and resistance checks with all power removed.
3. Check continuity of METER FUNCTION
Continuity
Go to 4.
Replace
switch (fig. FO-8).
defective
switch S3
4. Connect ME-26B/U across pin 13 of XA1;
+22 vdc
----------------
Replace
measure voltage.
defective
wiring.
2-11
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |