LOSS OF DC LOOP CURRENT REGULATION
Up
TM-11-5805-387-34-2 Modem Radion Teletypewriter MD-522A/RC (NSN
Next
ABNORMAL SCOPE PRESENTATION BUT NORMAL DISCRIMINATOR INDICATION ON TEST METER. (Cont)
TM 11-5805-387-34-2
MALFUNCTION/SYMPTOM
PROBABLE CAUSE
TEST PROCEDURE
INDICATION
YES
NO
3. Connect TS-799A/UGM-1 and test cable No. 3
Go to 4.
Replace
(para 2-4). Make the following tests across test
defective
points of receiver module A4 with the
module A4
AN/USM-207:
DISCR DRIVER 1 (MODE SELECTOR switch at
Space: 2,380 Hz
850 HZ)
Mark: 3,230 Hz
DISCR DRIVER 1 (MODE SELECTOR switch at
Space: 2,847.5 Hz ±2
85 HZ DIVERSITY)
Mark: 2,762.5 Hz ±2
DISCR DRIVER 2 (MODE SELECTOR switch at
Space:2,847.5 Hz ±2
85 HZ or 85 HZ DIVERSITY)
Mark: 2,762.5 Hz ±2
2,805 HZ NSK (MODE SELECTOR switch at
Space: 2,847.5 Hz ±2
85 HZ, 85 HZ DIVERSITY, or 85 HZ + VOICE)
Mark:2,762.5.Hz±2
DISCR AMPL (take reading between J3 and
Space: J3 higher
ground)
voltage than J2
DISCR AMPL (take reading between J2 and
Mark: J2 higher
ground)
voltage than J3